Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 270
Filtrar
1.
Emerg Infect Dis ; 30(13): S41-S48, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38561639

RESUMO

Serratia marcescens is an environmental gram-negative bacterium that causes invasive disease in rare cases. During 2020-2022, an outbreak of 21 invasive Serratia infections occurred in a prison in California, USA. Most (95%) patients had a history of recent injection drug use (IDU). We performed whole-genome sequencing and found isolates from 8 patients and 2 pieces of IDU equipment were closely related. We also identified social interactions among patients. We recovered S. marcescens from multiple environmental samples throughout the prison, including personal containers storing Cell Block 64 (CB64), a quaternary ammonium disinfectant solution. CB64 preparation and storage conditions were suboptimal for S. marcescens disinfection. The outbreak was likely caused by contaminated CB64 and propagated by shared IDU equipment and social connections. Ensuring appropriate preparation, storage, and availability of disinfectants and enacting interventions to counteract disease spread through IDU can reduce risks for invasive Serratia infections in California prisons.


Assuntos
Infecção Hospitalar , Desinfetantes , Prisioneiros , Infecções por Serratia , Humanos , Serratia marcescens/genética , Infecções por Serratia/epidemiologia , Prisões , Infecção Hospitalar/microbiologia , Surtos de Doenças , California/epidemiologia
2.
BMC Infect Dis ; 24(1): 266, 2024 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-38418981

RESUMO

BACKGROUND: Serratia marcescens is a gram-negative bacterium that is widespread in the environment. S. marcescens bacteremia can be fatal during pregnancy and cause persistent chorioamnionitis. This study reports an outbreak of Serratia marcescens bloodstream infection (BSI) among high-risk pregnant women in an obstetric ward. The purpose of this study is to report our experience with the usefulness of the ATP test in hospital environmental management and to confirm that bloodstream infections of patients with the same strain were correlated by WGS testing. METHODS: This retrospective study collected the data of inpatients with S. marcescens bacteremia in obstetric ward for high-risk pregnant women from August 22, 2021, to October 14, 2021. We performed: an adenosine triphosphate (ATP) bioluminescence test in the environment with a high-contact area; environmental culture; on-site monitoring and staff education; and whole-genome sequencing (WGS) to evaluate genetic relationships among S. marcescens isolates. RESULTS: S. marcescens BSI occurred in four consecutive patients. None of the patients had central venous catheters. An ATP bioluminescence test revealed that high-contact areas and areas for injection preparation were not clean (≥ 1000 relative light units). However, S. marcescens was not identified in the environmental cultures, likely due to intensive environmental cleaning and discarding of potentially contaminated specimens before the culture test. On-site monitoring and education were conducted for 1 month. There were no further reports of BSI until 6 months after the last patient was discharged. WGS performed on three isolates from three patients indicated that the isolated S. marcescens was likely from the same strain. CONCLUSIONS: We controlled an S. marcescens outbreak by improving environmental cleaning as well as education of and behavior changes in healthcare workers. Using the ATP bioluminescence test can provide feedback on environmental cleaning and education. WGS played a role in determining the spread of BSI caused by the same strain.


Assuntos
Bacteriemia , Infecção Hospitalar , Sepse , Infecções por Serratia , Gravidez , Humanos , Feminino , Recém-Nascido , Infecção Hospitalar/epidemiologia , Infecção Hospitalar/microbiologia , Gestantes , Serratia marcescens/genética , Estudos Retrospectivos , Infecções por Serratia/epidemiologia , Infecções por Serratia/microbiologia , Sepse/epidemiologia , Surtos de Doenças , Bacteriemia/epidemiologia , Bacteriemia/microbiologia , Hospitais , Trifosfato de Adenosina , Unidades de Terapia Intensiva Neonatal
3.
Ann Clin Microbiol Antimicrob ; 22(1): 108, 2023 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-38082303

RESUMO

OBJECTIVES: To evaluate the clinical and epidemiological impact of a new molecular surveillance strategy based on qPCR to control an outbreak by Serratia marcescens in a Neonatal Intensive Care Unit (NICU). METHODS: We design a specific qPCR for the detection of S. marcescens in rectal swabs of patients admitted to a NICU. We divided the surveillance study into two periods: (a) the pre-PCR, from the outbreak declaration to the qPCR introduction, and (b) the PCR period, from the introduction of the qPCR until the outbreak was solved. In all cases, S. marcescens isolates were recovered and their clonal relationship was analysed by PFGE. Control measures were implemented during the outbreak. Finally, the number of bloodstream infections (BSI) was investigated in order to evaluate the clinical impact of this molecular strategy. RESULTS: Nineteen patients colonized/infected by S. marcescens were detected in the pre-PCR period (October 2020-April 2021). On the contrary, after the PCR implementation, 16 new patients were detected. The PFGE revealed 24 different pulsotypes belonging to 7 different clonal groups, that were not overlapping at the same time. Regarding the clinical impact, 18 months after the qPCR implementation, no more outbreaks by S. marcescens have been declared in the NICU of our hospital, and only 1 episode of BSI has occurred, compared with 11 BSI episodes declared previously to the outbreak control. CONCLUSIONS: The implementation of this qPCR strategy has proved to be a useful tool to control the nosocomial spread of S. marcescens in the NICU.


Assuntos
Infecção Hospitalar , Sepse , Infecções por Serratia , Recém-Nascido , Humanos , Infecção Hospitalar/epidemiologia , Infecção Hospitalar/prevenção & controle , Infecção Hospitalar/diagnóstico , Unidades de Terapia Intensiva Neonatal , Serratia marcescens/genética , Infecções por Serratia/epidemiologia , Infecções por Serratia/prevenção & controle , Infecções por Serratia/diagnóstico , Reação em Cadeia da Polimerase , Sepse/epidemiologia , Surtos de Doenças
4.
J Hosp Infect ; 142: 58-66, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37774927

RESUMO

BACKGROUND: Nine surgical site infections caused by Serratia marcescens were diagnosed in neurosurgical patients in a 3500-bed hospital between 2nd February and 6th April 2022. OBJECTIVE: To trace the source of infections caused by S. marcescens to expedite termination of the outbreak and prevent future epidemics. METHODS: A review of all surgical procedures and cultures yielding S. marcescens since February 2022 was conducted. Samples were collected from patients and environmental sources. S. marcescens isolates were characterized by antibiotic susceptibility testing. Whole-genome sequencing (WGS) was used to investigate genetic relationships. Resistance genes, virulence genes and plasmid replicons were identified. RESULTS: S. marcescens was isolated from patients' puncture fluid, cerebrospinal fluid and other secretions, and was also cultured from the barbers' haircutting tools, including leather knives, slicker scrapers and razors. In total, 15 isolates were obtained from patients and eight isolates were obtained from haircutting tools. All isolates exhibited identical antibiotic resistance patterns. WGS revealed close clustering among the 23 isolates which differed significantly from previous strains. Three resistance genes and nine virulence-associated genes were detected in all isolates, and 19 of 23 isolates harboured an MOBP-type plasmid. The results confirmed an outbreak of S. marcescens, which was traced to contaminated haircutting tools in the hospital barber shop. The outbreak ended after extensive reinforcement of infection control procedures and re-education of the barbers. CONCLUSIONS: These results highlight the risk of postoperative infections related to pre-operative skin preparation, and demonstrate the value of next-generation sequencing tools to expedite outbreak investigations.


Assuntos
Infecção Hospitalar , Infecções por Serratia , Humanos , Infecção Hospitalar/epidemiologia , Infecção Hospitalar/diagnóstico , Surtos de Doenças , Genômica , Hospitais , Infecções por Serratia/epidemiologia , Serratia marcescens/genética
5.
Rev Argent Microbiol ; 55(3): 251-254, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37100682

RESUMO

Carbapenemase-producing-Serratia marcescens isolates, although infrequent, are considered important nosocomial pathogens due to their intrinsic resistance to polymyxins, which limits therapeutic options. We describe a nosocomial outbreak of SME-4-producing S. marcescens in Buenos Aires city which, in our knowledge, represents the first one in South America.


Assuntos
Infecção Hospitalar , Infecções por Serratia , Humanos , Serratia marcescens , beta-Lactamases , Infecções por Serratia/epidemiologia , Infecção Hospitalar/epidemiologia , América do Sul/epidemiologia , Surtos de Doenças
6.
Appl Environ Microbiol ; 89(5): e0010523, 2023 05 31.
Artigo em Inglês | MEDLINE | ID: mdl-37067412

RESUMO

Compelling evidence suggests a contribution of the sink environment to the transmission of opportunistic pathogens from the hospital environment to patients in neonatal intensive care units (NICU). In this study, the distribution of the opportunistic pathogen Serratia marcescens in the sink environment and newborns in a NICU was investigated. More than 500 sink drain and faucet samples were collected over the course of five sampling campaigns undertaken over 3 years. Distribution and diversity of S. marcescens were examined with a modified MacConkey medium and a high-throughput short-sequence typing (HiSST) method. Sink drains were an important reservoir of S. marcescens, with an average of 44% positive samples, whereas no faucet sample was positive. The genotypic diversity of S. marcescens was moderate, with an average of two genotypes per drain, while the spatial distribution of S. marcescens was heterogeneous. The genotypic profiles of 52 clinical isolates were highly heterogeneous, with 27 unique genotypes, of which 71% of isolates were found in more than one patient. S. marcescens acquisition during the first outbreaks was mainly caused by horizontal transmissions. HiSST analyses revealed 10 potential cases of patient-to-patient transmission of S. marcescens, five cases of patient-to-sink transmission, and one bidirectional transfer between sink and patient. Environmental and clinical isolates were found in sink drains up to 1 year after the first detection, supporting persisting drain colonization. This extensive survey suggests multiple reservoirs of S. marcescens within the NICU, including patients and sink drains, but other external sources should also be considered. IMPORTANCE The bacterium Serratia marcescens is an important opportunistic human pathogen that thrives in many environments, can become multidrug resistant, and is often involved in nosocomial outbreaks in neonatal intensive care units (NICU). We evaluated the role of sinks during five suspected S. marcescens outbreaks in a NICU. An innovative approach combining molecular and culture methods was used to maximize the detection and typing of S. marcescens in the sink environment. Our results indicate multiple reservoirs of S. marcescens within the NICU, including patients, sink drains, and external sources. These results highlight the importance of sinks as a major reservoir of S. marcescens and potential sources of future outbreaks.


Assuntos
Infecção Hospitalar , Infecções por Serratia , Humanos , Recém-Nascido , Unidades de Terapia Intensiva Neonatal , Infecção Hospitalar/microbiologia , Serratia marcescens/genética , Infecções por Serratia/epidemiologia , Surtos de Doenças
7.
Neonatology ; 120(2): 176-184, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36623500

RESUMO

BACKGROUND: Serratia marcescens may cause severe nosocomial infections, mostly in very low birth weight infants. Since S. marcescens exhibits by far the highest adjusted incidence rate for horizontal transmission, it can cause complex outbreak situations in neonatal intensive care units. OBJECTIVE: The aim of this study was to establish a fast and highly sensitive colonization screening for prompt cohorting and barrier nursing strategies. METHODS: A probe-based duplex PCR assay targeting the 16S rRNA gene of S. marcescens was developed and validated by using 36 reference strains, 14 S. marcescens outbreak- and nonoutbreak isolates, defined by epidemiological linkage and molecular typing, and applied in 1,347 clinical specimens from 505 patients. RESULTS AND CONCLUSIONS: The novel PCR assay proved to be highly specific and had an in vitro sensitivity of 100 gene copies per reaction (∼15 bacteria). It showed a similar (in laryngeal/tracheal specimens) or even higher (in rectal/stoma swabs) in vivo sensitivity in comparison to routine microbial culture and was much quicker (<24 h vs. 2 days). By combining different oligonucleotide primers, there was robust detection of genetic variants of S. marcescens strains. PCR inhibition was low (1.6%) and observed with rectal swabs only. Cohort analysis illustrated applicability of the PCR assay as a quick tool to prevent outbreak scenarios by allowing rapid decisions on cohorting and barrier nursing. In summary, this novel molecular screening for colonization by S. marcescens is specific, highly sensitive, and substantially accelerates detection.


Assuntos
Infecção Hospitalar , Infecções por Serratia , Recém-Nascido , Lactente , Humanos , Unidades de Terapia Intensiva Neonatal , Serratia marcescens/genética , RNA Ribossômico 16S , Infecção Hospitalar/epidemiologia , Infecção Hospitalar/prevenção & controle , Infecção Hospitalar/microbiologia , Reação em Cadeia da Polimerase , Surtos de Doenças/prevenção & controle , Infecções por Serratia/diagnóstico , Infecções por Serratia/epidemiologia , Infecções por Serratia/prevenção & controle
8.
Pediatr Infect Dis J ; 42(2): 152-158, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-36638403

RESUMO

BACKGROUND: Serratia spp. are opportunistic, multidrug resistant, Gram-negative pathogens, previously described among preterm infants in case reports or outbreaks of infection. We describe Serratia late-onset infection (LOI) in very preterm infants in a large, contemporary, nationally representative cohort. METHODS: In this secondary analysis of prospectively collected data of preterm infants born 401-1500 grams and/or 22-29 weeks gestational age from 2018 to 2020 at 774 Vermont Oxford Network members, LOI was defined as culture-confirmed blood and/or cerebrospinal fluid infection > 3 days after birth. The primary outcome was incidence of Serratia LOI. Secondary outcomes compared rates of survival and discharge morbidities between infants with Serratia and non-Serratia LOI. RESULTS: Among 119,565 infants, LOI occurred in 10,687 (8.9%). Serratia was isolated in 279 cases (2.6% of all LOI; 2.3 Serratia infections per 1000 infants). Of 774 hospitals, 161 (21%) reported at least one Serratia LOI; 170 of 271 (63%) cases occurred at hospitals reporting 1 or 2 Serratia infections, and 53 of 271 (20%) occurred at hospitals reporting ≥5 Serratia infections. Serratia LOI was associated with a lower rate of survival to discharge compared with those with non-Serratia LOI (adjusted relative risk 0.88, 95% CI: 0.82-0.95). Among survivors, infants with Serratia LOI had higher rates of tracheostomy, gastrostomy and home oxygen use compared with those with non-Serratia LOI. CONCLUSIONS: The incidence of Serratia LOI was 2.3 infections per 1000 very preterm infants in this cohort. Lower survival and significant morbidity among Serratia LOI survivors highlight the need for recognition and targeted prevention strategies for this opportunistic nosocomial infection.


Assuntos
Doenças do Prematuro , Infecções por Serratia , Lactente , Recém-Nascido , Humanos , Recém-Nascido Prematuro , Unidades de Terapia Intensiva Neonatal , Infecções por Serratia/epidemiologia , Recém-Nascido de muito Baixo Peso , Idade Gestacional , Serratia
9.
Minerva Pediatr (Torino) ; 75(2): 180-187, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-29072041

RESUMO

BACKGROUND: Serratia marcescens (Sm) is a known cause of infection and colonization in neonates receiving intensive care. The aim of this study was to identify the risk factors for colonization and infection with Sm in Neonatal Intensive Care Unit (NICU) of a tertiary care Hospital. METHODS: A case-control study was conducted from January to December 2011 in neonates admitted to the NICU. Cases are patients with a microbiologically confirmed infection or colonization, controls were randomly chosen among patients admitted to the same NICU. RESULTS: Globally, 39 acquired infections or colonizations were identified. Among factors related to pregnancy, only premature delivery was independently associated to the risk of infection; as well as mechanical ventilation and catheterization for parenteral nutrition, considering indwelling devices. Prolonged administration with antibiotics were also related to the risk of infection. Among Sm strains which have been tested to antibiotics, all have been resistant to amoxicillin/clavulanic acid and to colistin. CONCLUSIONS: This study confirms the association between Sm infection or colonization and low gestational age. Invasive medical devices and medications, strictly necessary in care-support of preterm neonates, are likely related to Sm infection too. Preventive control strategies are expected to be effective in the control of Sm spread in NICUs.


Assuntos
Infecção Hospitalar , Infecções por Serratia , Recém-Nascido , Gravidez , Feminino , Humanos , Estudos de Casos e Controles , Unidades de Terapia Intensiva Neonatal , Serratia marcescens , Infecção Hospitalar/epidemiologia , Infecção Hospitalar/microbiologia , Infecção Hospitalar/prevenção & controle , Infecções por Serratia/epidemiologia , Infecções por Serratia/microbiologia , Infecções por Serratia/prevenção & controle , Antibacterianos/uso terapêutico , Itália/epidemiologia , Hospitais
10.
Infect Control Hosp Epidemiol ; 44(6): 891-897, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35929043

RESUMO

OBJECTIVE: Investigation of the origin of a Serratia marcescens outbreak in a neonatal intensive care unit. DESIGN: Retrospective case-control study. SETTING: Regional level 3 perinatal center in Germany. PATIENTS: This study included 4 S. marcescens-positive and 19 S. marcescens-negative neonates treated between February 1 and February 26, 2019, in the neonatal intensive care unit. METHODS: A case-control study was performed to identify the source of the outbreak. The molecular investigation of S. marcescens isolates collected during the outbreak was performed using pulsed-field gel electrophoresis and next-generation sequencing. RESULTS: The retrospective case-control study showed a significant correlation (P < .0001) between S. marcensens infection or colonization and consumption of donor milk that had tested negative for pathogenic bacteria from a single breast milk donor. Pulsed-field gel electrophoresis and next-generation sequencing retrospectively confirmed an S. marcescens strain isolated from the breast milk of this donor as the possible origin of the initial outbreak. The outbreak was controlled by the implementation of an infection control bundle including a multidisciplinary infection control team, temporary nutrition of infants with formula only and/or their mother's own milk, repeated screening of all inpatients, strict coat and glove care, process observation, retraining of hand hygiene and continuous monitoring of environmental cleaning procedures. CONCLUSIONS: Low-level contaminated raw donor milk can be a source of infection and colonization of preterm infants with S. marcescens even if it tests negative for bacteria.


Assuntos
Infecção Hospitalar , Infecções por Serratia , Lactente , Feminino , Recém-Nascido , Humanos , Unidades de Terapia Intensiva Neonatal , Infecção Hospitalar/prevenção & controle , Recém-Nascido Prematuro , Serratia marcescens/genética , Estudos Retrospectivos , Estudos de Casos e Controles , Infecções por Serratia/epidemiologia , Surtos de Doenças , Leite Humano , Eletroforese em Gel de Campo Pulsado
12.
Enferm Infecc Microbiol Clin (Engl Ed) ; 40(5): 248-254, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35577443

RESUMO

OBJECTIVE: Serratia marcescens is a Gram-negative bacterium that is found in hospital environments and commonly associated with outbreaks in neonatal units. One S. marcescens isolate was detected from a bloodstream culture from a neonate in our hospital that was followed by an outbreak. The aim of this study was to describe the molecular epidemiology of a S. marcescens outbreak in the neonatal unit. METHODS: In order to investigate the outbreak, weekly surveillance rectal swabs were submitted for culture from all patients admitted in this unit from August to September 2018. Environmental samples were obtained from potential sources in September 2018. Typing of isolates was performed by pulsed field gel electrophoresis (PFGE). In addition, we studied the in vitro activity of chlorhexidine against S. marcescens. RESULTS: During this period, 146 infants were hospitalised in our neonatal unit, of which 16 patients had a S. marcescens-positive sample. A total of 36 environmental surveillance samples were collected, and one sample from a stethoscope from an incubator of a colonized baby was positive for S. marcescens. All the 18 isolates, including the isolate from the stethoscope, belonged to a single PFGE cluster. We found that very low concentrations of chlorhexidine, even with application times close to 0 achieved significant reductions in the amount of S. marcescens. CONCLUSION: A unique clone of S. marcescens caused this outbreak, including isolates from patients and from one stethoscope. The outbreak was controlled with the early implementation of specific control measures.


Assuntos
Infecção Hospitalar , Infecções por Serratia , Clorexidina , Infecção Hospitalar/epidemiologia , Infecção Hospitalar/microbiologia , Infecção Hospitalar/prevenção & controle , Surtos de Doenças , Humanos , Recém-Nascido , Unidades de Terapia Intensiva Neonatal , Infecções por Serratia/epidemiologia , Infecções por Serratia/microbiologia , Serratia marcescens , Espanha/epidemiologia , Centros de Atenção Terciária
13.
J Hosp Infect ; 121: 128-131, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34906601

RESUMO

Serratia marcescens is a nosocomial pathogen with carbapenem resistance, which limits the availability of effective treatment options. In this study, molecular characterization of GES-5 carbapenemase-producing S. marcescens isolated from an outbreak in Japan was undertaken. Comparative genetic analysis revealed that the blaGES-5-encoding plasmid p2020-O-9 is a unique plasmid contributing to carbapenem resistance. Furthermore, this study highlights the need for surveillance programmes to monitor both novel and commonly occurring carbapenemases in clinical settings.


Assuntos
Infecção Hospitalar , Infecções por Serratia , Antibacterianos/farmacologia , Infecção Hospitalar/epidemiologia , Surtos de Doenças , Humanos , Japão/epidemiologia , Testes de Sensibilidade Microbiana , Plasmídeos/genética , Infecções por Serratia/epidemiologia , Serratia marcescens/genética , beta-Lactamases/genética
14.
Am J Infect Control ; 50(2): 223-225, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34687798

RESUMO

COVID-19 dedicated units were created early in the pandemic. Despite their need, factors specific to these units can possibly increase the risk of bacterial cross-contamination between COVID-19 patients. We report a Serratia marcescens outbreak in a COVID-19 intensive care unit, later discussing factors specific to COVID-19 units that may facilitate bacterial cross-contamination in such units, and raising awareness for such an issue.


Assuntos
COVID-19 , Infecção Hospitalar , Infecções por Serratia , Infecção Hospitalar/epidemiologia , Surtos de Doenças , Humanos , Recém-Nascido , Controle de Infecções , Unidades de Terapia Intensiva , Unidades de Terapia Intensiva Neonatal , SARS-CoV-2 , Infecções por Serratia/epidemiologia , Serratia marcescens
15.
Artigo em Inglês | MEDLINE | ID: mdl-34574734

RESUMO

Serratia marcescens (SM) is a Gram-negative bacterium that is frequently found in the environment. Since 1913, when its pathogenicity was first demonstrated, the number of infections caused by SM has increased. There is ample evidence that SM causes nosocomial infections in immunocompromised or critically ill patients admitted to the intensive care units (ICUs), but also in newborns admitted to neonatal ICUs (NICUs). In this study, we evaluated the possible genetic correlation by PFGE between clinical and environmental SM strains from NICU and ICU and compared the genetic profile of clinical strains with strains isolated from patients admitted to other wards of the same hospital. We found distinct clonally related groups of SM strains circulating among different wards of a large university hospital. In particular, the clonal relationship between clinical and environmental strains in NICU and ICU 1 was highlighted. The identification of clonal relationships between clinical and environmental strains in the wards allowed identification of the epidemic and rapid implementation of adequate measures to stop the spread of SM.


Assuntos
Infecção Hospitalar , Infecções por Serratia , Infecção Hospitalar/epidemiologia , Surtos de Doenças , Eletroforese em Gel de Campo Pulsado , Humanos , Recém-Nascido , Unidades de Terapia Intensiva Neonatal , Infecções por Serratia/epidemiologia , Serratia marcescens/genética
16.
J Hosp Infect ; 111: 184-188, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33582202

RESUMO

Early postoperative infections due to Serratia marcescens have been reported by both clinicians and microbiologists in our teaching hospital. Here, we present an interlinked clinical, epidemiological, environmental and genomic investigation of this outbreak due to a T-shaped intraoperative probe contaminated by S. marcescens used during peroperative ultrasonography in laparoscopic liver resection.


Assuntos
Infecção Hospitalar , Contaminação de Equipamentos , Infecções por Serratia , Infecção da Ferida Cirúrgica , Ultrassonografia/instrumentação , Infecção Hospitalar/epidemiologia , Surtos de Doenças , Humanos , Infecções por Serratia/epidemiologia , Serratia marcescens , Infecção da Ferida Cirúrgica/epidemiologia , Infecção da Ferida Cirúrgica/microbiologia
17.
J Hosp Infect ; 111: 148-154, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33581246

RESUMO

BACKGROUND: Serratia marcescens is notorious for its increasing antimicrobial resistance and potential to cause outbreaks in neonatal intensive care units (NICUs). A promising tool in outbreak investigations is whole-genome sequencing (WGS). OBJECTIVES: To describe a S. marcescens outbreak (2018-2019) in an NICU and discuss which infection control measures contributed to containment, addressing the potential of WGS. METHODS: S. marcescens isolates from patients and the environment isolated during the 2018-2019 NICU outbreak were analysed. In comparison, isolates from previous presumed NICU outbreaks and adult blood cultures were included. WGS and whole-genome multi-locus sequence typing analysis were performed. RESULTS: Sixty-three S. marcescens isolates were analysed. The 2018-2019 outbreak was divided into three clusters, including four environmental strains (drains, N=3; baby scale, N=1). The strains differed significantly from those of an NICU outbreak in 2014 and adult blood cultures. Besides standard infection control measures, the siphons were replaced and weekly decontamination was performed with acetic acid 10%. Seven acquired-resistance genes and 29 virulence-associated genes were detected. CONCLUSIONS: It was assumed that both neonates and drains were reservoirs of S. marcescens cross-contamination via the hands of healthcare workers and parents. Initially, standard measures, including hand hygiene, were reinforced. However, definitive containment was achieved only after replacement of the siphons and weekly decontamination with acetic acid. WGS enables faster recognition of an outbreak with accurate mapping of the spread, facilitating the implementation of infection control measures. WGS also provides interesting information about the spread of antibiotic resistance and virulence genes.


Assuntos
Infecção Hospitalar , Unidades de Terapia Intensiva Neonatal , Infecções por Serratia , Adulto , Infecção Hospitalar/epidemiologia , Descontaminação , Surtos de Doenças , Contaminação de Equipamentos , Humanos , Lactente , Tipagem de Sequências Multilocus , Infecções por Serratia/epidemiologia , Serratia marcescens/genética , Sequenciamento Completo do Genoma
19.
J Hosp Infect ; 108: 7-14, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33181279

RESUMO

BACKGROUND: Serratia marcescens frequently causes outbreaks in healthcare settings. There are few studies using high-throughput sequencing (HTS) that analyse S. marcescens outbreaks. We present the analysis of two outbreaks in neonatal intensive care units (NICUs) in hospitals from the Comunitat Valenciana (CV, Spain) and the impact of using different reference genomes. METHODS: DNA from cultured isolates was extracted and sequenced by HTS using Illumina NextSeq. Reads were mapped against two reference genomes, strains UMH9 and Db11, and the unmapped fraction of the genomes was assembled to fully genetically characterize the isolates. FINDINGS: Isolates from the first outbreak were identical to the UMH9 reference, an unrelated isolate obtained three years earlier in the USA. This did not occur when the Db11 strain, a standard reference for S. marcescens, was used as the reference for mapping. To check whether UMH9 was a widely distributed clone spreading in the CV, the second outbreak isolates were mapped against this reference. They were not closely related to this strain, and this outbreak could be defined as such regardless of the reference used for mapping the reads. CONCLUSIONS: The choice of the reference for genomic analysis of outbreaks is a critical decision. In the case of the first outbreak, this choice changed the interpretation of the results drastically, allowing or preventing the definition of the outbreak according to the reference used. Although HTS is a powerful tool for epidemiological analysis, it is still essential to collect microbiological and epidemiological data for the correct interpretation of the results.


Assuntos
Infecção Hospitalar , Surtos de Doenças , Infecções por Serratia , Serratia marcescens/classificação , Células Clonais , Infecção Hospitalar/epidemiologia , Humanos , Recém-Nascido , Unidades de Terapia Intensiva Neonatal , Testes de Sensibilidade Microbiana , Infecções por Serratia/epidemiologia , Espanha
20.
Nephrology (Carlton) ; 26(3): 255-261, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33150699

RESUMO

AIM: To study the epidemiology and clinical outcomes of catheter-related infections of Serratia species in peritoneal dialysis (PD) patients. METHODS: We retrospectively reviewed the patient characteristics, antibiotics susceptibility/resistance patterns and treatment outcomes of exit site infection (ESI) and peritonitis due to Serratia in PD patients during the period of 2004 to 2017. RESULTS: One hundred and sixty-one patients had Serratia ESI, of which 10 (6.2%) progressed to tunnel tract involvement and 11 (6.8%) developed PD peritonitis. Nineteen (11.8%) patients with Serratia ESI failed to respond to medical treatment and required catheter removal. Fifty-six (34.8%) patients had repeat Serratia ESI, which occurred at 12.9 ± 13.6 months after the previous episode. Twenty-two patients had Serratia peritonitis, which accounted for 1% of peritonitis during the study period. Ten (45.5%) patients responded to medical treatment while 12 (54.5%) patients required catheter removal. Nine patients (36.4%) failed to resume PD and were converted to long-term haemodialysis. Two patients had repeat peritonitis at 2 months and 3 years, respectively, after the initial episode. Serratia species in PD patients showed high rates of resistance to ampicillin, and first- and second-generation cephalosporins, but were generally susceptible to aminoglycosides, carboxy-/ureido-penicillins and carbapenems. CONCLUSION: Our results suggest that Serratia ESI show low risk of progression to peritonitis and favourable response to medical therapy, while Serratia peritonitis was associated with high rates of catheter removal and peritoneal failure.


Assuntos
Antibacterianos , Infecções Relacionadas a Cateter , Falência Renal Crônica , Diálise Peritoneal , Infecções por Serratia , Serratia/isolamento & purificação , Antibacterianos/administração & dosagem , Antibacterianos/efeitos adversos , Antibacterianos/classificação , Infecções Relacionadas a Cateter/epidemiologia , Infecções Relacionadas a Cateter/microbiologia , Infecções Relacionadas a Cateter/fisiopatologia , Infecções Relacionadas a Cateter/terapia , Cateteres de Demora/efeitos adversos , Cateteres de Demora/microbiologia , Remoção de Dispositivo/estatística & dados numéricos , Farmacorresistência Bacteriana , Feminino , Hong Kong/epidemiologia , Humanos , Falência Renal Crônica/epidemiologia , Falência Renal Crônica/terapia , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde , Diálise Peritoneal/efeitos adversos , Diálise Peritoneal/instrumentação , Diálise Peritoneal/métodos , Peritonite/epidemiologia , Peritonite/etiologia , Infecções por Serratia/epidemiologia , Infecções por Serratia/etiologia , Infecções por Serratia/fisiopatologia , Infecções por Serratia/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...